Skip to content
PlanElec logo

PlanElec MCP server

Which MCP servers are PlanElec's own, from the official registry and from asking its own domain, whether they answer, and what they offer. A program checked each of these, nobody copied them from a product page.

read 2026-11-06

← Back to PlanElec

Whose server it is
  • Registry namebe.planelec/calculatorsverified in the MCP registry

The registry name sits under planelec.be. The registry only lets a publisher use that namespace after proving control of the domain through DNS or HTTP.

When we asked itchecked 2026-11-06
  • Stateanswerschecked 2026-11-06
  • Tools8
  • Server calls itselfplanelec
  • Server version0.2.0
  • Protocol version2025-06-18

On 2026-11-06 the server answered initialize and tools/list without a sign-in. First answer in 495 ms.

Should an agent connect it

Connect it
  • On Nov 22, 2026 we called its read-only tools following a fixed scenario, and 1 of 1 steps returned what the check expects.

Said by rules from the measurements above. The likely first call is a model's pick from the tool list; read its description before relying on it.

Measured daily

daily checks: 17, the first on 2026-11-06
  • INITE MCP score100 of 100answers 100 · definitions 100 · context 100 · connects 100
  • Checked by calling it1 of 1 steps passedlatest run Nov 22, 2026, read-only calls only
  • Answered100% of days17 of 17 daily checks
  • Median first answer525 ms
  • Space in an agent's context≈ 2,884 tokensthe definitions of all its tools (8), which an agent carries on every turn
  • Tool definitionsA · 100 of 100
  • Typed results8 of 8 toolsdeclared outputSchema: results come typed, read once
  • Every tool passes all six checks.

Worth a look

None of the five warning signs in these definitions.

A program checks the server once a day: initialize and tools/list, no model. Tokens are the definitions' length at about four characters a token. The grade averages six checks of every tool's name, description, schema and annotations; it says how well the tools are described, not whether they work. The score weighs what was measured and nothing else: answering (25%), doing the product's job (25%), definitions (20%), context (10%), use (10%) and how readily a client connects (10%). A part that was not measured is left out, and a hidden instruction caps the score at 40. The state of vendors' MCP servers: method and numbers →

Security2026-11-22

Grade A, 98 of 100, checked 2026-11-22 · 1 failed

Full report →

Tools it offers8 tools · read 2026-11-22
  • check_inverter_c10_26described by the server

    Checks whether a PV inverter, battery inverter or other power-generating unit (PGU) is on the Synergrid C10/26 list of devices homologated for connection to the Belgian grid. Returns the outcome (found, found_with_limitations, expired…

  • suggest_inverter_c10_26described by the server

    Typeahead for the Synergrid C10/26 list: given a partial brand or model name, returns matching brands with device counts or, once a brand is recognised, its homologated models. Use this to resolve an ambiguous device name before calling…

  • get_inverter_datasheetdescribed by the server

    Returns manufacturer datasheet data for an inverter from the Synergrid C10/26 list: maximum DC voltage, MPPT count and range, current limits per MPPT, start voltage, maximum PV power, battery capability, optimizer architecture, links to…

  • size_cable_areidescribed by the server

    Calculates the required copper or aluminium cable cross-section for a residential circuit under the Belgian AREI/RGIE: design current, voltage drop per cross-section, protection check against the breaker rating and the recommended…

  • calculate_led_stripdescribed by the server

    Calculates power, current (total and per channel), required feed points, power-supply size and the extra-low-voltage feed cable for an analogue LED strip (5/12/24/48 V DC; single colour, CCT, RGB, RGBW, RGB+CCT). Provide the strip length…

  • search_help_guidesverified Nov 22, 2026

    Searches the PlanElec guides about getting started, automatic planning, document exports, AREI self-check coverage, floor plan import, symbols and circuits in the visitor’s current language. Returns up to five guides with title, summary…

  • search_regelwerkseen, not called yet

    Searches Book 1 of the Belgian AREI/RGIE (Royal Decree on electrical installations) in the language of the text: Dutch, French or German; English uses the German text. Returns up to ten articles with number, title, an excerpt, the edition…

  • get_regelwerk_articledescribed by the server

    Returns the text of one article of Book 1 of the Belgian AREI/RGIE by its number (for example 4.2.4.3 or "AREI 7.1.4.3"), in the language of the text (Dutch, French or German; English uses the German text), with the edition, change…

How to connect

Add the server to your MCP client config. Claude Desktop, Cursor and most other clients read this shape:

{
  "mcpServers": {
    "calculators": {
      "type": "http",
      "url": "https://planelec.be/mcp/public"
    }
  }
}

Add it

Claude Code, in a terminal

claude mcp add --transport http planelec https://planelec.be/mcp/public

Add to CursorAdd to VS Code

claude.ai, ChatGPT and other clients: add https://planelec.be/mcp/public as a custom connector in the settings.

Other servers listed as PlanElec's
  • be.planelec/planelecanswers, requires sign-inverified in the MCP registry

Each line is something a program found when it went looking: the registry entry, the server's own answer, a spec that parses. A missing line means we did not find it, not that it does not exist.