Skip to content
The Grate Guys logo

The Grate Guys MCP server

Which MCP servers are The Grate Guys's own, from the official registry and from asking its own domain, whether they answer, and what they offer. A program checked each of these, nobody copied them from a product page.

read 2026-11-16

← Back to The Grate Guys

Whose server it is
  • Registry namecom.thegrateguys/toolsverified in the MCP registry

The registry name sits under thegrateguys.com. The registry only lets a publisher use that namespace after proving control of the domain through DNS or HTTP.

When we asked itchecked 2026-11-16
  • Stateanswerschecked 2026-11-16
  • Tools15
  • Server calls itselfThe Grate Guys
  • Server version1.0.0
  • Protocol version2025-06-18

On 2026-11-16 the server answered initialize and tools/list without a sign-in. First answer in 1797 ms.

Should an agent connect it

Not proven either way yet
  • Whether its tools do the product's job has not been judged yet.
  • Checked on 6 of the 7 days it takes to judge reliability.

Said by rules from the measurements above. The likely first call is a model's pick from the tool list; read its description before relying on it.

Measured daily

daily checks: 6, the first on 2026-11-16
  • INITE MCP scoreafter a weeka score needs 7 daily checks: 6 so far
  • Answeredmeasuring6 of the 7 daily checks it takes to print a share
  • Median first answer140 ms
  • Space in an agent's context≈ 5,781 tokensthe definitions of all its tools (15), which an agent carries on every turn
  • Tool definitionsA · 100 of 100
  • Typed results0 of 15 toolsdeclared outputSchema: results come typed, read once
  • Every tool passes all six checks.

Worth a look

None of the five warning signs in these definitions.

A program checks the server once a day: initialize and tools/list, no model. Tokens are the definitions' length at about four characters a token. The grade averages six checks of every tool's name, description, schema and annotations; it says how well the tools are described, not whether they work. The score weighs what was measured and nothing else: answering (25%), doing the product's job (25%), definitions (20%), context (10%), use (10%) and how readily a client connects (10%). A part that was not measured is left out, and a hidden instruction caps the score at 40. The state of vendors' MCP servers: method and numbers →

Security2026-11-22

Grade A, 94 of 100, checked 2026-11-22 · 3 failed

Full report →

Tools it offers15 tools · read 2026-11-22
  • bar_grating_load_calculator

    Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.

  • bar_grating_load_tables

    Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.

  • aluminum_stainless_bar_grating_load_calculator

    Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.

  • accessible_grating_opening_checker

    Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.

  • galvanizing_coating_thickness_calculator

    Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.

  • guard_and_railing_code_checker_ontario

    Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.

  • steel_stair_calculator_ontario

    Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.

  • steel_weight_calculator

    Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.

  • trench_drain_grate_load_class

    The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.

  • bollard_spacing_and_footing_calculator

    Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and explains crash ratings.

  • steel_beam_lintel_span_check

    The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule. Not a stamped design.

  • catch_basin_grate_and_frame_size_finder

    Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on the ledge, and lists the EN 1433 load…

  • fence_and_gate_post_spacing_and_weight

    Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.

  • trench_drain_flow_capacity_calculator

    The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with the narrowest channel that works.

  • loading_dock_height_and_leveler_check

    The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and whether two makers published working…

How to connect

Add the server to your MCP client config. Claude Desktop, Cursor and most other clients read this shape:

{
  "mcpServers": {
    "tools": {
      "type": "http",
      "url": "https://thegrateguys.com/mcp"
    }
  }
}

Add it

Claude Code, in a terminal

claude mcp add --transport http thegrateguys https://thegrateguys.com/mcp

Add to CursorAdd to VS Code

claude.ai, ChatGPT and other clients: add https://thegrateguys.com/mcp as a custom connector in the settings.

OpenAPI spec

16 paths, read 2026-11-16. Open the spec ↗

Each line is something a program found when it went looking: the registry entry, the server's own answer, a spec that parses. A missing line means we did not find it, not that it does not exist.