Servidor MCP de Calc
Quais servidores do registro oficial de MCP são de Calc, se respondem e o que oferecem. Um programa verificou cada item; nada foi copiado da página do produto.
lido em 2026-10-18
- Nome no registroengineer.calc/calcverificado no registro MCP
O nome no registro fica sob calc.engineer. O registro só libera esse espaço de nomes para quem prova controle do domínio por DNS ou HTTP.
- Estadorespondeverificado em 2026-10-18
- Ferramentas89
- O servidor se chamacalc-engineer
- Versão do servidor1.0.0
- Versão do protocolo2025-06-18
Em 2026-10-18 o servidor respondeu a initialize e tools/list sem login. Primeira resposta em 921 ms.
fsplCalculate free-space path loss (FSPL) in decibels using the ITU-R P.525 standard formula. Given a frequency in MHz and distance in kilometres, returns the expected signal attenuation in an ideal line-of-sight radio link with no obstacles…
link_budgetCompute a full RF link budget from transmitter power, frequency, distance, and antenna gains. Calculates EIRP, free-space path loss (ITU-R P.525), received power at the receiver, and link margin relative to an optional receiver…
dipoleCalculate physical dimensions of a dipole antenna for a given frequency. Returns half-wave or quarter-wave element length in metres, feet, and inches. A half-wave dipole is the most common resonant antenna with approximately 2.15 dBi…
microstripCalculate PCB microstrip trace width for a target characteristic impedance using the Hammerstad-Jensen closed-form equations. Given target impedance (Z0), substrate dielectric constant (er), substrate height, and copper weight, returns…
dbm_convertConvert a power level in dBm to milliwatts, watts, dBW, and RMS voltage across a given impedance. dBm is the standard unit for RF power referenced to 1 milliwatt. This tool is essential when interfacing datasheets (which use dBm) with…
noise_figure_cascadeCalculate the cascaded noise figure of a multi-stage receiver chain using the Friis formula. Each stage has a noise figure and gain in dB. The first stage dominates overall system noise, which is why low-noise amplifiers (LNAs) are placed…
vswrConvert between VSWR, return loss, and reflection coefficient — provide any one parameter and get all related impedance-mismatch metrics. Computes VSWR (voltage standing wave ratio), return loss in dB, reflection coefficient (gamma)…
attenuator_piDesign a Pi-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical Pi-pad network. The Pi attenuator uses two shunt…
attenuator_teeDesign a Tee-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical T-pad network. The Tee attenuator uses two series…
fresnel_zoneCalculate the Fresnel zone radius at the midpoint of a radio link. Given frequency in MHz, link distance in kilometres, and zone number (1-5), returns the Fresnel zone radius in metres and feet, plus the 60% clearance threshold used in…
wavelength_freqConvert between radio frequency and wavelength. Provide either frequency in MHz or wavelength in metres, and get the full set of equivalent values: frequency in MHz and GHz, wavelength in metres, centimetres, millimetres, and feet…
spice_templateGenerate a complete SPICE netlist from a parameterized template. Supports common circuit topologies: low-pass RC filter, voltage divider, common emitter amplifier. Returns a ready-to-simulate netlist string that can be passed directly to…
spice_simulateRun a SPICE circuit simulation directly in the worker. Accepts a standard SPICE netlist and performs operating-point (.op), DC sweep (.dc), AC frequency sweep (.ac), or transient (.tran) analysis using a built-in modified-nodal-analysis…
lora_airtimeCalculates LoRa packet time-on-air using the Semtech AN1200.13 formula. Computes symbol duration, preamble time, payload symbol count, effective data rate, and the minimum transmission interval for 1% duty cycle compliance. Essential for…
snr_marginComputes LoRa link SNR margin by comparing received power against the noise floor and the spreading-factor-dependent demodulation threshold from the Semtech SX1276 datasheet. Calculates receiver noise floor from thermal noise (-174…
channel_utilizationEstimates Meshtastic or LoRa mesh channel utilization percentage based on node count, message rate, and per-packet airtime. Determines how much of the shared radio channel is occupied and computes the maximum number of nodes before…
lora_range_estimateEstimates LoRa maximum communication range by computing the free-space path loss (FSPL) link budget and applying terrain-dependent correction factors. Calculates total link budget from transmit power, antenna gains, and receiver…
lora_sensitivityCalculates LoRa receiver sensitivity from spreading factor, bandwidth, and noise figure using the Semtech SX1276 datasheet SNR thresholds. Computes the noise floor from thermal noise density (-174 dBm/Hz), channel bandwidth, and receiver…
duty_cycle_budgetCalculates LoRa duty cycle budget for EU868, US915, AS923, and AU915 regulatory regions. Computes maximum messages per hour, minimum transmission interval, and effective data rate under regional duty cycle constraints. EU868 and AS923…
meshtastic_rangeEstimates Meshtastic node communication range using real hardware profiles and firmware channel presets. Combines device-specific TX power and antenna gain (Heltec V3, RAK WisBlock, T-Beam, T-Beam Supreme, Station G2) with firmware modem…
eirp_complianceChecks EIRP (Effective Isotropic Radiated Power) compliance against regional regulatory limits for LoRa and Meshtastic operation. Computes EIRP from transmit power, antenna gain, and cable loss, then compares against FCC (US, 36 dBm)…
meshtastic_powerCalculates Meshtastic node power consumption and battery runtime using device-specific power profiles and firmware role-based duty cycling. Models sleep, RX, and TX current draw for Heltec V3, RAK WisBlock, T-Beam, T-Beam Supreme, and…
lora_param_optimizerRecommends optimal LoRa spreading factor, bandwidth, and TX power based on target range, terrain, and optimization priority. Iterates through all SF (7-12) and BW (125/250/500 kHz) combinations, computing achievable range, airtime, data…
zfs_capacityCalculate usable ZFS pool capacity for any RAID level including stripe, mirror, raidz1, raidz2, and raidz3. Computes raw capacity, parity overhead, data disk count, usable terabytes after ZFS metadata overhead (checksums, block pointers…
zfs_ramCalculate recommended RAM and ARC sizing for a ZFS storage pool based on workload type, pool size, deduplication status, and L2ARC cache size. Computes minimum and recommended RAM in gigabytes, ARC target size, and dedup table overhead…
tcp_throughputCalculate maximum TCP throughput using the Bandwidth-Delay Product (BDP) formula. Given link bandwidth and round-trip latency, computes the BDP (maximum in-flight data), achievable throughput with a given TCP window size, link utilization…
wireguard_mtuCalculate the optimal MTU for a WireGuard VPN tunnel interface with a detailed overhead breakdown. Accounts for WireGuard header (32 bytes), outer IP header (20 bytes IPv4 or 40 bytes IPv6), UDP header (8 bytes), and optional PPPoE…
subnet_calculatorCalculate IPv4 subnet details from CIDR notation. Parses a CIDR block (e.g. 192.168.1.0/24) and returns the network address, broadcast address, subnet mask, wildcard mask, first and last usable host addresses, total and usable host…
raid_iopsEstimate RAID array IOPS performance and latency for ZFS and traditional RAID configurations. Calculates maximum read IOPS, write IOPS (accounting for write penalty/amplification per RAID level), blended IOPS for a configurable read/write…
power_costCalculate total power consumption, electricity cost, and circuit requirements for a homelab. Enter each device's wattage to get daily/monthly/yearly kWh and cost at your local electricity rate. Accounts for cooling overhead via PUE (Power…
cooling_btuEstimate the cooling load (BTU/hr) for a homelab or server closet based on equipment wattage, room dimensions, insulation quality, and solar exposure. All electrical power converts to heat — this tool calculates equipment heat output…
rack_capacityQuick rack space and weight sizing calculator for homelab and small data center racks. Enter your devices with their height in rack units, weight, and wattage to get total utilization, remaining free space, weight totals in lbs and kg…
network_bandwidthPlan and validate network link capacity for homelab workloads. Determine whether a 1G, 2.5G, 10G, or faster link can handle your concurrent streams (VMs, backups, media, iSCSI). Calculates effective bandwidth after TCP/IP overhead, total…
thermal_enclosureEstimate steady-state thermal behaviour of a rectangular enclosure (server rack, electronics housing, equipment cabinet) using a lumped-parameter energy balance with natural-convection and radiation correlations, or forced-flow air energy…
heatsink_cfdAnalyze a forced-convection fin-array heatsink using established channel-flow correlations (developing laminar Nusselt, fin efficiency tanh(mH)/mH, parallel-plate friction). Computes base-to-air thermal resistance, pressure drop, base and…
pcb_thermalEstimate PCB component temperatures by solving a thermal resistance network (thermal↔electrical analogy) with the built-in MNA solver. Each component gets a junction node (package θjb from a typical-datasheet table), a local board node…
battery_lifeCalculates battery runtime and energy capacity given cell capacity in mAh, nominal voltage, and average current draw. Accounts for real-world discharge efficiency (Peukert-adjacent derating) to produce effective capacity, total energy in…
wire_gaugeDetermines the minimum AWG (American Wire Gauge) conductor size for a given current, voltage, one-way cable distance, and maximum allowable voltage drop percentage. Supports copper and aluminum conductors. Computes round-trip resistance…
solar_sizingSizes an off-grid solar power system by calculating the number of panels and battery bank capacity required for a given daily energy consumption. Accounts for system losses (inverter, wiring, charge controller), battery…
ups_runtimeEstimates UPS (Uninterruptible Power Supply) backup runtime from battery specifications and connected load. Takes VA rating, watt rating, load in watts, and battery configuration (count, voltage, amp-hours) to compute effective stored…
mah_to_whConverts battery capacity from milliamp-hours (mAh) to watt-hours (Wh), kilowatt-hours (kWh), and joules (J) given the nominal cell voltage. This is the most common battery unit conversion needed when comparing cells rated in mAh (e.g…
watts_to_ampsConverts electrical power in watts to current in amps (and milliamps) for a given voltage, using the DC power formula P = V * I. Also computes the implied load resistance via Ohm's law (R = V / I) assuming a purely resistive load. This is…
voltage_dropCalculates voltage drop across a conductor run given current, wire length, AWG gauge, system voltage, and conductor material (copper or aluminum). Computes round-trip resistance, voltage drop in volts and percent, voltage at the load end…
battery_charge_timeEstimates battery charge time given capacity in mAh, charge current in mA, charger efficiency, and initial state of charge. Accounts for real-world charging losses (typically 80-90% efficient) to produce time in hours and minutes, energy…
solar_load_auditCalculates total daily energy consumption from an appliance list — the critical first step before sizing solar panels or batteries. Enter each appliance with its wattage, hours of daily use, and quantity. Outputs total daily kWh (with…
solar_roiCalculates solar system return on investment, payback period, and levelized cost of energy (LCOE). Models year-by-year savings accounting for panel degradation, utility rate inflation, federal Investment Tax Credit (ITC), state rebates…
battery_autonomyCalculates how many days a battery bank can sustain loads without solar input — critical for off-grid and backup power sizing. Accounts for depth of discharge, round-trip efficiency (lithium vs lead-acid), minimum state of charge, and…
string_sizingCalculates optimal solar panel string and MPPT configuration based on panel electrical specs, inverter/charge-controller MPPT limits, and site temperature extremes. Applies temperature coefficients to determine Voc at minimum temperature…
generator_offsetCompares total cost of ownership between a fuel generator and a solar+battery system over a configurable time horizon. Calculates yearly and cumulative costs for generator-only, solar-only (amortized), and hybrid scenarios. Accounts for…
wire_ampacityDetermine minimum wire gauge using NEC Table 310.16 ampacity ratings with full derating. Looks up base ampacity for copper or aluminum conductors at 60°C, 75°C, or 90°C insulation rating, then applies NEC 310.15(C)(1) ambient temperature…
inverter_sizingSize a DC-to-AC inverter for off-grid solar, battery backup, or mobile power systems. Computes the required continuous VA rating from total load watts and power factor, estimates surge capacity for motor-starting loads (3-7x rated power)…
pcb_layoutTurn a SPICE netlist into a fab-ready 2-layer PCB: assigns real footprints (0805, TO-92, DO-35, DIP-8, headers, LED, radial-cap), auto-places components (connectivity-aware; or use your own placement), routes a 2-layer maze router with…
voltage_dividerCalculates output voltage, current draw, and power dissipation for a resistive voltage divider. Given an input voltage Vin and two resistor values R1 (upper) and R2 (lower), computes Vout = Vin * R2 / (R1 + R2), divider current…
rc_filterComputes the cutoff frequency, time constant, impedance, and phase shift of a first-order RC filter. Supports both lowpass and highpass topologies. The cutoff frequency is f = 1/(2*pi*R*C) where the signal is attenuated by 3 dB. The time…
lc_resonanceCalculates the resonant frequency of an LC circuit, along with optional Q factor and bandwidth when series resistance is provided. The resonant frequency f0 = 1/(2*pi*sqrt(L*C)) is where inductive and capacitive reactances cancel. Used…
impedance_matchDesigns an L-network impedance matching circuit between two real impedances at a given frequency. Computes the required shunt and series reactive components (inductor and capacitor) to transform the source impedance to the load impedance…
trace_widthCalculates the minimum PCB trace width for a given current using the IPC-2221 standard formula. The IPC-2221 empirical equation relates current capacity to cross-sectional area and temperature rise: I = k * dT^0.44 * A^0.725, where…
ohms_lawSolves Ohm's Law and the power equation given any two of four electrical quantities: voltage (V), current (I), resistance (R), and power (P). Uses V=IR, P=VI, P=I^2R, and P=V^2/R to derive the missing two values. Fundamental for every…
resistor_color_codeDecodes 4-band or 5-band resistor color codes into resistance value, tolerance, and min/max range. Accepts an ordered array of color names (left-to-right as printed on the resistor body). Supports standard EIA color codes including gold…
led_resistorCalculates the current-limiting resistor for driving one or more LEDs in series from a DC supply. Computes the exact resistance from R = (Vsupply - n*Vf) / I, then selects the nearest E24 standard resistor value. Reports the actual…
As primeiras 60 de 89, na ordem do servidor.
Como conectar
Adicione o servidor à configuração do seu cliente MCP. Claude Desktop, Cursor e a maioria dos outros clientes leem este formato:
{
"mcpServers": {
"calc": {
"type": "http",
"url": "https://calc.engineer/mcp"
}
}
}Cada linha é algo que um programa encontrou ao procurar: o registro, a resposta do próprio servidor, uma especificação que se lê. Linha ausente quer dizer que não encontramos, não que não exista.